Cooktop Low-Profile Hood Installation 12
Wall Hoods—Recirculating Installation
INTERNAL BLOWER MODELS
IMPORTANT NOTE:
A recirculation kit is required for this
installation. The kit is available through your authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
Locate the electrical supply through the wall within the
shaded area shown in the illustration on page 6. Install
ductwork as outlined on pages 8–9.
MOUNT HOOD TO WALL
Follow the same instructions for mounting the hood to the
wall as outlined for ducted installations on page 10.
ATTACH TELESCOPIC FLUE
Assemble the three support brackets for the telescopic
flue as shown in illus 4 on page 10. The width of the
bracket assembly can be adjusted. With screws and
anchors provided, attach the bracket assembly to the
ceiling so that it is positioned along the axis with the hood.
Mount the flange on the hood to correspond with the air
outlet point shown in illus 9 below.
Fit 5" (127) flexible metal ducting (not provided) to the
air baffle of the hood and seal with duct tape. Attach the
air baffle to the upper flue with four screws as shown in
illus 10. Connect the other end of the flexible ducting to
the flange.
WIRING CONNECTIONS
Follow the same instructions for wiring connections as
outlined for ducted installations on page 11.
INSTALL CHARCOAL FILTER
First remove the grease filter(s). To access the filter(s),
gently press up on the front edge of the bottom panel and
allow it to rotate downward. Push the handle outward and
pull the grease filter(s) downward to remove. Then install
the charcoal filter by inserting the two filter clips in the
slots and turning the filter towards the inside of the hood.
Reinstall the grease filter(s) using the reverse procedure.
Refer to illus 11 below.
GREASE
FILTER
CHARCOAL
FILTER
Illus 11.