10
Blower connection at hood:
1)
Run conductors (2-wire plus ground) from
the in-line or remote blower to the hood's
wiring box marked "motor connection".
2)
Remove the cover from the wiring box and
remove one knockout as shown in illus 9.
3)
Secure the conduit to the wiring box
through a conduit connector.
4)
Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5)
Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
In-line or remote blower connection:
1)
Make electrical connections at the in-line or
remote blower. Refer to instructions
provided with the in-line or remote blower.
WOLF COOKTOP LOW-PROFILE HOODS
WALL HOODS – DUCTED
IN-LINE OR REMOTE BLOWER
Follow the installation steps for wall hoods on
pages 8–9. Additional wiring connections must
be made for the in-line or remote blower.
Installation instructions will be provided with
the remote blower.
WIRING
IMPORTANT NOTE:
The ventilation hood
must be properly grounded. It should be
installed by a qualified electrician in accor-
dance with all applicable national and local
electrical codes.
Complete the wiring procedure for the power
connection at the hood on the previous page,
then make the following connections.
Illus. 9
BOX MARKED
MOTOR
CONNECTION
REMOTE
BLOWER